Hybrid energy storage system optimal sizing for urban electrical bus regarding battery thermal behavior
Abstract
This paper proposes an algorithm for sizing the hybrid energy storage system of an urban electrical bus regarding battery thermal behavior. The aim of this study is to get the supercapacitors optimal contribution part in the hybrid energy storage system to keep the battery temperature within its allowable limit. A semi-active parallel topology that uses supercapacitors as a main source of energy is considered. According to the bus mechanical parameters and the ARTEMIS driving cycle, the power and energy demand are calculated. Using mathematical models for the battery, supercapacitors and DC-DC converter, several simulations are performed for different hybridization percentages. While observing the evolution of battery temperature, the most favorable hybridization percentage is defined.
Keywords
Battery; Battery thermal behavior; Buck-boost DC/DC converter; Fully electrical bus; Hybrid energy storage system; Supercapacitor
Full Text:
PDFDOI: http://doi.org/10.11591/ijece.v10i3.pp2894-2911
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
International Journal of Electrical and Computer Engineering (IJECE)
p-ISSN 2088-8708, e-ISSN 2722-2578
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).