Reducing the hygroscopic swelling in MEMS sensor using different mold materials

Pinki Kumari, Kuldeep Singh, Anuj Singal

Abstract


Today, Hygroscopic swelling is one of the biggest challenging problem of Epoxy mold compound (EMC) in packaging with Microelectromechanical system (MEMS) devices. To overcome this hygroscopic swelling problem of EMC and guard the devices, MEMS devices are molded in this paper with different Mold Compound (MC) i.e. titanium and ceramic etc. during their interconnection with the board. Also, a comparatively performance analysis of this various mold compound with MEMS pressure sensor has been studied in this paper at 60% humidity, 140 mol/m3 saturation concentration and 25 oC. It was observed that hygroscopic swelling does not take place in the titanium mold compound. But, titanium is very costly so we have to consider something cheaper material i.e. ceramic in this paper. The Hygroscopic swelling in Ceramic Mold Compound after 1 year is nearly 0.05mm which is very less than epoxy.

Keywords


MEMS EMC MC Hygroscopic Swelling

Full Text:

PDF


DOI: http://doi.org/10.11591/ijece.v10i1.pp494-499

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

International Journal of Electrical and Computer Engineering (IJECE)
p-ISSN 2088-8708, e-ISSN 2722-2578

This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).