Electromagnetic interference measurement for axle counters light rapid transit railway in Indonesia

Yudhistira Yudhistira, Yoppy Yoppy, Elvina Trivida, Tyas Ari Wahyu Wijanarko, Hutomo Wahyu Nugroho, Dwi Mandaris

Abstract


The measurement and analysis of electromagnetic interference (EMI) from light rapid transit (LRT) axle counters against magnetic field interference in Indonesia has been carried out. The low-cost magnetic sensors were developed according to the British Standard (BS) EN 50592:2016. The measurement setup and magnetic field limit were based on the British Standard EN 50592:2016 and ERA/ERTMS/033281 standard. Two frequency range of the measurements, lower and higher frequencies with two different train running mode, acceleration mode and deceleration mode were applied in this research. The results in lower frequency range (10 to 100 kHz) were very close to the limit value in both acceleration and deceleration mode, especially at the 30 to 50 kHz for the y and z directions. Although there may possibly magnetic interference at low frequencies, most of the magnetic field emissions were still in acceptable range.

Keywords


Axle counters; Electromagnetic interference; Light rail transit; Magnetic field; Railway

Full Text:

PDF


DOI: http://doi.org/10.11591/ijece.v12i5.pp4632-4639

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

International Journal of Electrical and Computer Engineering (IJECE)
p-ISSN 2088-8708, e-ISSN 2722-2578

This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).